Thornhill, ON — Serving All of Canada

Field Services

Precision Analysis That Catches Faults Early

We deploy to your facility, acquire data on all critical rotating assets, and deliver a full ISO-standard diagnostic report with findings, severity ratings, and prioritized corrective action recommendations.

1

Asset Survey & Baseline Acquisition

Complete walkdown of all critical rotating equipment. Establish measurement points per ISO 10816 / 20816. Collect baseline vibration signatures and thermal data.

2

Multi-Parameter Analysis

Time-waveform analysis, FFT spectrum analysis, cepstrum analysis, and envelope demodulation to identify fault type, severity, and probable root cause.

3

ISO Severity Classification

Each finding classified against ISO 10816-3 zones A through D. Clear green/yellow/red status for every asset inspected.

4

Actionable Report & Follow-Up

Written diagnostic report delivered within 48 hours. Includes vibration spectra, thermal images where applicable, findings summary, and recommended repair timeline.

Iraj Roy performing vibration analysis in field
Fan vibration analysis onsite
Vibration analysis at robotics facility

Equipment Coverage

Every Rotating Asset in Your Facility

AC / DC Motors
Centrifugal Fans
Axial Blowers
Compressors
Chillers
Centrifugal Pumps
Gearboxes
Ball Mills
Industrial Mixers
Belt Conveyors
HVAC Units
Cooling Towers
Centrifuges
Steam Turbines
Agitators
Rotary Dryers
Chain Drives
Couplings

Fault Detection

What We Find Before It Fails You

Years of field data and diagnostic experience let us identify faults that pass undetected by conventional PM programs.

Bearing Inner / Outer Race Defects

Detected 4–8 weeks before audible noise or catastrophic failure using envelope analysis.

Imbalance & Misalignment

1x, 2x, 3x harmonic patterns diagnosed with root-cause corrective guidance included.

Resonance Conditions

Natural frequency identification prevents operating near resonance zones that accelerate damage.

Looseness & Structural Issues

Structural looseness and soft-foot conditions identified and differentiated from rotating looseness.

Gear Mesh Defects

GMF harmonics and sidebands analyzed for wear, cracking, and tooth profile deterioration.

Standards We Follow

ISO 10816-3

Vibration severity evaluation for industrial machinery above 15 kW

ISO 20816

Measurement and evaluation of machine vibration — updated standard

ISO 13373

Condition monitoring of machines — vibration measurement procedures

CMVA Guidelines

Canadian Machinery Vibration Association analyst certification framework

Delivered By

CMVA Cat III Analyst ICML MLT II CMRP Infrared Level I

Schedule a Facility Assessment

We will identify your highest-risk assets and develop a prioritized vibration monitoring plan — at no cost.